- 28 -
Replace LLC every 2 years or 1000 hours
Mixture ratio (for reference only) :
Ambienr
temperature
(Celsius)
-15
-20
-30
Mixture ratio
30% 35% 45%
8.2.3 Coolant Capacity
( Unit: L)
Total Coolant Volume ( including reservoir tank)
22.8 (1.5)
The value of ( ) shows the reservoir tank`s volume.
8.3
Checking Fan Belt
Also refer to the user’s manual for Engine separately
:Injuries
Before performing any equipment check or maintenance, stop the engine,
and remove the engine key. A person performing the maintenance should always
keep the key.
Close all doors and place locks during operating this equipment, to avoid injuries
by unintentionally touching cooling fan and fan belt.
:Burns
Do not touch the engine and muffler during operation and immediately after stopping
the equipment, for the temperature can reach extremely high
8.3.1 Tension
Tension should be optimum when the fan belt has 10 to
15mm slacks, when applying finger pressure (about
98N{approximately 10kgf}) at midpoint between fan
pulley and alternator pulley.
Danger
Caution